Pages

Saturday, August 20, 2011

DS4243 Disk Shelves


  • DS4243 FRUs, connectors, controllers & switches
  • Configuration and tasks related to DS4243
  • Field Replaceable Units (FRUs) related to the DS4243
    • The DS4243 is a FRU in an of itself comprised of multiple other FRUs:
      • Chassis
        • 4U weighing 110lbs
      • PSUs
        • two required for SATA drive shelves
          • two empty slots must contain blank PSUs to provide air flow
        • four required for SAS drive shelves
        • Labeled 1-4 from left to right, top to bottom
      • IOM3
        • input-output modules
        • provide multi-path high availability
        • each IOM3 contains two ACP ports and two SAS ports
      • Ear Covers
        • left and right ear covers; left is for the digital readout of the shelf ID as well as the shelf LEDs.  The shelf-ids are under the right ear cover.
        • hidden by left ear cover is shelf ID switch, must power cycle shelf to have new shelf ID take effect
      • HDDs
        • supports 24 disk drives, labeled 0-24 from top left to bottom right\
        • SAS or SATA but not mixed, however different shelves in same stack can be mixed, use blank panels for empty slots to ensure proper air flow
      • SAS HBAs (controller)
        • quad-port PCIe
          • in 3000+ series FAS/V models
        • dual-port PCIe mini
          • only supported in FAAS2050 controller
      • QSFP Copper Cables
        • used to connect SAS HBAs to controller or other disk shelves IOM3 SAS PCIe controller
      • Ethernet (ACP) Cables
        • extra shielding for increased EMI performance
        • from IOM3 to IOM3 or IOM3 to controller
      • Cable connectors
        • QSFP & 10/100
          • Quad-small-form factor pluggable connectors are keyed, and should be gently inserted into IOM3 SAS ports.
          • 10/100 connect 10Mbps/100Mbps provide ACP Ethernet network
        • two 10/100 and two QSFP on each IOM3
          • QSFP is 4-wide meaning 4 lanes per port times 3Gbps for max of 12Gbps
      • LEDs
        • 51 per chassis
        • 3 shelf LEDs and 48 disk drive LEDs
          • Disk LEDs:  Power (top) Fault (bottom)
          • shelf LEDs: Power (top), Fault (middle), Activity (bottom)
        • PSU LEDs
          • each PSU has 4 LEDs:
            • AC Fail, PCM OK, Fan Fail, DC Fail
        • IOM3 LEDs
          • each IOM3 has 7 LEDs: IOM fault, Ethernet Activity & Ethernet Up/Down, then SAS activity